High Country Tek, Inc.
HGC-2 Initial Installation Guide
Electronic Control Solutions for the Global Fluid Power Industry
www.hctcontrols.com
Beware of HIGH VOLTAGE when operating any
generator system high voltage can be LETHAL
observe ALL laws, by-laws and health & Safety
recommendations for your immediate location,
state and/or country.
HGC-2 Product Features:
Full PID closed loop speed controller for use with AC generator systems
Customer selectable voltages and frequencies for global applications
Operates with all major OEM electro-hydraulic valve and pump equipment
Industry standard Deutsch 12 way connector protected to >IP69K ( NEMA 6P )
Environmentally hardened by ’Solid’ potting with flame retardant materials
Full CE compliance for confident global application on all mobile equipment
Comprehensive on-line literature, manuals, user guides and application information
Fully configurable by PC based user interface for set-up and diagnostics
Fast, easy and reliable development-to-production timeline across multiple platforms
U.S.A. designed, built and supplied
Vista de página 0
1 2 3 4 5 6 7 8

Resumo do Conteúdo

Página 1 - HGC-2 Product Features:

High Country Tek, Inc. HGC-2 Initial Installation Guide Electronic Control Solutions for the Global Fluid Power Industry www.hctcontrols.com Bewa

Página 2 - NEVER do the following:

2 ALWAYS do the following:  Take a few minutes to FULLY read THESE information / data sheets BEFORE starting.  Isolate this unit from all othe

Página 3 - 4 -Solenoid Connection O/P

3 Electronic Controller Solutions for the Global Fluid Power Industry HGC-2 Connection Information: Housing Type:- HCT unique ‘encapsulated’ bl

Página 4 - AC volts

4 Electronic Controller Solutions for the Global Fluid Power Industry Graphical User Interface: SupplyThrottle SettingEngineHydraulic PumpHydraulic

Página 5

5 Electronic Controller Solutions for the Global Fluid Power Industry Controller Set-up: PID Tuning B C System Repeatability & Stability: Run O

Página 6

6 Electronic Controller Solutions for the Global Fluid Power Industry Controller Set-up: PID Tuning Initial explanation of operation: 1. See red

Página 7

7 Electronic Controller Solutions for the Global Fluid Power Industry Controller Set-up: PID Tuning Tuning the PID loop on the HGC-2-XX: The HGC-2-

Página 8 - Nevada City, CA, 95959

8 CC – Constant Current Mode: This mode is used to verify the system is stable under a constant command signal. The current mode would be set to a