021-MVP-F Rev A MVP-F User Manual 10
Copyright © High Country Tek, Inc. 2013
MVP-F Closed-loop Controller
Parameter List
The following table outlines the MVP-F parameters as well as the limits and units of measure for each parameter.
Parameter
Limits
Units
MVP-Fxx-xxx
Version #
Mode
See Mode Description
Mode #
Proportional gain
0 to 100
%
Integral gain
0 to 100
%
Derivative gain
0 to 100
%
PID loop time
1 to 30
# cycles
Dither frequency
50, 75, 100, 125, 150, 175, 200, 225, 250, 275,
300, 350, 400, 500, 1000
Hz
Minimum command
0 to 10.0 (0 to 20.0)
V (mA)
Maximum command
0 to 10.0 (0 to 20.0)
V (mA)
Minimum feedback
0 to 10.0 (0 to 20.0)
V (mA)
Maximum feedback
0 to 10.0 (0 to 20.0)
V (mA)
Minimum output
0 to 600
*
mA
Maximum output
0 to 600
*
mA
Command below min
Off, Limit, Fault
Command above max
Off, Limit, Fault
Feedback below min
Off, Normal, Fault
Feedback above max
Off, Normal, Fault
Command
V (mA)
Feedback
V (mA)
Error
Output current
mA
Supply voltage
Volts
Fault status
Fault
*
0 to 1.2A for 12A version, 0 to 2.5A for 25A version