021-MVP-R Rev A MVP-R User Manual 5
Copyright © High Country Tek, Inc. 2013
MVP-R Ramping Controller
The MVP-R controller drives proportional solenoid valves with adjustable ramp times.
Once configured, the settings are permanently stored in the controller memory.
MVP-R Features
Easily configured using HCT Graphical User Interface (GUI) or HCT Hand Held Interface (HHI)
LED indication of power, output current and fault status
Permanently sealed, standard DIN 43650 Form A connector body with pre-wired 18AWG PVC cable
Single coil applications, programmable enable input
Output limits are independently adjustable
Adjustable output with short circuit protection
Adjustable ramp up and ramp down times (RP1 has ramp up only)
Operating Specifications
Valve current + 20mA (Quiescent Max)
80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300.
(Select OFF for 1000Hz)
Enable Input Voltage (RP2)
Operating Temperature Range
-20º to 70º C (operating); -40º to 85º C (storage)
Inch: 2.4 L x 1.2 W x 0.75 H; Mm: 60 L x 30 W x 19 H