Hydraulic Fan System Controller : HFS - 2
Software Setup Guide
– Dashboard level:
1
2
13
3
5
6
9
10
11
4
7
8
12
At the observer level, Dashboard, ‘Help’ and ‘Quit’ is the
only options available on the menu bar
1
Clickin
this button starts the data lo
in
rocess.
3
.
Alarm and Status text window.
Error messages are in RED text.
The window stays as above while there are no errors or
alarms reported by the system and/or controller.
2
General display area for controller information and input /
output status.
Analog needle display and digital readout of ‘real-time’
output current to proportional valve drive.
10
Analog bar graph and digital readout of ‘real-time’ output
current as a % of the maximum set.
11
ALL of the parameters available in the item drop down
menu as well as other profile settings are logged for a
period of 256 samples . After the logging period, a popup
window asks for file name and storage location.
This file is saved with a *.csv extension which allows direct
import, reading and graphing in Microsoft Excel.
5
Status of the reverse ( Purge ) cycle ( auto or manual ) if
reverse is enabled and/or triggered.
12
Window where ‘Real-time’ graphing of selected parameter
4
Clicking the HCT logo, prompts the user for the password
level required:-
13
.
Drop down list of available parameters for display.
5
Digital representation of the parameter being displayed in
6
13
4
Real time graphing window
4
Wh th HCT l i li k d thi i d
22
Selects Slow, Medium or Fast graph time base setting.
7
Selects Graphic window scaling between FULL scale or
AUTO. Auto gives better resolution for lower values.
8
en
e
ogo
s c
c
e
,
s w
n
ow
will open and reset the access level to NONE.
• You must enter a password to enter a new
level.