P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools Page | 143
* For Active High connections, the SPST switch will be connected between
the appropriate input and (+) power.
* For Active Low connections, the SPST switch will be connected between
the appropriate input and ground.
10.9 DVC70 Hardware Connections
DVC70
18 Pin Metri-Pak connector (P12)
Pin Function Pin Function
A1 RXD D1
A2 TXD D2
A3 RTS D3
B1 SIG COM E1 (-) PWR BAT
B2 E2 (+) PWR IGN
B3 E3 ALARM OUT
C1 F1 PWR COM
C2 F2 PWR COM
C3 F3 PWR COM
DVC70
5 Pin J1939 connecter (P13)
Pin Function
1 NC
2 NC
3 NC
4 CAN H
5 CAN L
10.10 DVC80 Hardware Connections
DVC80
18 Pin Metri-Pak connector (P14)
Pin Function Pin Function
A1 RXD D1 J1939 CAN H
A2 TXD D2 J1939 CAN L
A3 SIG COM D3
B1 SIG COM E1 (+) POWER IN
B2 (+) 5VDC E2
Comentários a estes Manuais