P/N: 021-00154, Rev. A.6 - updated for V4.7 Tools Page | 50
Digital Input
Name Description Range
Name
1
Set/Get the state of the switch False or Off, True or
On
Name.RealRPM The Unsigned Integer Value of the RPM. For Pulse
inputs Only
0 to 9999
Name.PulseTimeout Get/Set Pulse Timeout for Loss of Signal 0 to 65535
Name.PulsesPerRev Get/Set Pulses Per Revolution 0 to 9999
Name.Counter Get/Set Unsigned Integer Value of the Counter.
Pulse inputs Only
0 to 65535
Name.LOS Loss of Signal flag set after time out. For Pulse
inputs Only
False (Pulses ok),
True (No Pulse Input)
Universal and Analog Input
Name Description Range
Name
1
Get 0 to 100% regardless of direction 0% to 100%
(Min Volts to Center
Volts)
NameLo
1
Get 0 to 100% of Min to (Center - Deadband)
only if Center is enabled
0% to 100%
(Center Volts to Max
Volts)
NameHi
1
Get 0 to 100% of (Center + Deadband) to Max
only if Center is enabled
0% to 100%
Name.Dir Get the Upper or Lower Side of the Analog
Input only if Center is enabled.
Lower Side voltage is lower than the Upper
Side
False (Lower Side), True
(Upper Side)
Name.RawVolts Volts or mAmps (ma = universal input ma
select)
0 to 1023 * Scale
2
Name.RefVolts Reference Volts = RefVolts * .00489 0 to 1023
Name.RampVolts Ramped Volts = RampVolts * Scale Factor 0 to 1023 * Scale
2
Name.MinVolts When Name = 0% (i.e. Center not enabled) 0 to 1023 * Scale
2
Name.MaxVolts When Name = 100% 0 to 1023 * Scale
2
Name.MinLimit Threshold for Name.MinF 0 to 1023 * Scale
2
Name.MaxLimit Threshold for Name.MaxF 0 to 1023 * Scale
2
Name.RefMinLimit Threshold for Name.MinRF 0 to 1023 * Scale
2
Name.RefMaxLimit Threshold for Name.MaxRF 0 to 1023 * Scale
2
Name.CenterVolts Where Center Volts 0 to 1023 * Scale
2
Name.Deadbandv Plus and minus volts about CenterVolts 0 to 1023 * Scale
2
NameX.RampUp RampUp * .01 = Time Min to Max (Seconds) 0.0 to 65.00 s
NameX.RampDown RampDown * .01 = Time Max to Min (Seconds) 0.0 to 65.00 s
NameX Where NameX = NameLo, NameHi if Center is
enabled NameX = Name if Center is not
enabled
Name.MinF Status Flag set if Voltage is less than Min Limit False (ok), True (Outside
Limit)
Name.MaxF Status Flag set if Voltage is greater than Max
Limit
Range: False (ok), True
(Outside Limit)
Name.MinRF Status Flag set if Voltage is less than
Reference Min Limit
False (ok), True (Outside
Limit)
Name.MaxRF Status Flag set if Voltage is greater than
Reference Max Limit
False (ok), True (Outside
Limit)